Beaufort Co (Southside)

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.

1. System Information

Contact Information

Incomplete

Water System Name: Beaufort Co (Southside)   PWSID: 04-07-040
Mailing Address:111 West Second Street
Washington, NC 27889
Ownership:County
 
Contact Person:Erick JenningsTitle:Water Systems Manager
Phone:252-975-0720Cell/Mobile:--
 
Secondary Contact:Christina Smith Phone:252-975-0720
Mailing Address:111 West Second Street
Washington, NC 27889
Cell/Mobile:--
Distribution System
Line Type Size Range (Inches) Estimated % of lines
Ductile Iron 4-16 5.00 %
Polyvinyl Chloride 2-12 95.00 %
What are the estimated total miles of distribution system lines?   138 Miles
How many feet of distribution lines were replaced during 2002?   0 Feet
How many feet of new water mains were added during 2002?   0 Feet
How many meters were replaced in 2002?   0
How old are the oldest meters in this system?   5 Year(s)
How many meters for outdoor water use, such as irrigation, are not billed for sewer services?   0
What is this system's finished water storage capacity?   0.5000 Million Gallons
Has water pressure been inadequate in any part of the system since last update? Line breaks that were repaired quickly should not be included.   No
Programs
Does this system have a program to work or flush hydrants?   No, None
Does this system have a valve exercise program?   No, None
Does this system have a cross-connection program?   No
Does this system have a program to replace meters?   No
Does this system have a plumbing retrofit program?   No
Does this system have an active water conservation public education program?   No
Does this system have a leak detection program?   No
Water Conservation
What type of rate structure is used?   One-Charge
How much reclaimed water does this system use?   0.0000 MGD   For how many connections?   0
Does this system have an interconnection with another system capable of providing water in an emergency?   No

2. Water Use Information

Service Area
Sub-Basin(s)% of Service Population
Pamlico River & Sound (15-3)0 %
Tar River (15-1)0 %
County(s)% of Service Population
Beaufort0 %
What was the year-round population served in 2002?   2,740
Has this system acquired another system since last report?   
Water Use by Type
Type of Use Metered
Connections
Metered
Average Use (MGD)
Non-Metered
Connections
Non-Metered
Estimated Use (MGD)
Residential 1,124 0.1290 0 0.0000
Commercial 5 0.0010 0 0.0000
Industrial 0 0.0000 0 0.0000
Institutional 0 0.0000 0 0.0000

How much water was used for system processes (backwash, line cleaning, flushing, etc.)?   0.0090 MGD

Water Sales
Purchaser PWSID Average
Daily Sold
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Aurora 04-07-020 0.0000 0 0.0000 6 Emergency
Beaufort Co WD VI 04-07-612 0.0000 0 0.0000 10 Emergency

3. Water Supply Sources

Monthly Withdrawals & Purchases
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Jan 0.1300 0.1770 May 0.1550 0.2220 Sep 0.1470 0.1870
Feb 0.1300 0.1820 Jun 0.1620 0.3760 Oct 0.1450 0.1740
Mar 0.1330 0.1800 Jul 0.1840 0.3790 Nov 0.1510 0.2320
Apr 0.1380 0.1790 Aug 0.1660 0.1950 Dec 0.1350 0.1880

Ground Water Sources
Name or Number Average Daily Withdrawal (MGD) Max Day Withdrawal (MGD) 12-Hour Supply
(MGD)
CUA Reduction Year Offline Use Type
MGD Days Used
Well 1 0.1000 263 0.227 0.5400 CUA0 Regular
Well 2 0.0840 329 0.182 0.5400 CUA0 Regular
Ground Water Sources (continued)
Name or Number Well Depth (Feet) Casing Depth
(Feet)
Screen Depth (Feet) Well Diameter (Inches) Pump Intake Depth (Feet) Metered?
Top Bottom
Well 1 244 199 199 239 12 198 Yes
Well 2 247 202 202 242 12 198 Yes
Are ground water levels monitored?   Yes, Monthly
Does this system have a wellhead protection program?   No
Water Purchases From Other Systems
Seller PWSID Average
Daily Purchased
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Aurora 04-07-020 0.0000 0 0.0000 6 Emergency
Water Treatment Plants
Plant Name Permitted Capacity
(MGD)
Is Raw Water Metered? Is Finished Water Ouput Metered? Source
Beaufort Co District VII 0.7500 Yes Yes Ground
Did average daily water production exceed 80% of approved plant capacity for five consecutive days during 2002?  No
     If yes, was any water conservation implemented?  
Did average daily water production exceed 90% of approved plant capacity for five consecutive days during 2002?  No
     If yes, was any water conservation implemented?  
Are peak day demands expected to exceed the water treatment plant capacity in the next 10 years?  No

4. Wastewater Information

Monthly Discharges
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Jan 0.0000 May 0.0000 Sep 0.0000
Feb 0.0000 Jun 0.0000 Oct 0.0000
Mar 0.0000 Jul 0.0000 Nov 0.0000
Apr 0.0000 Aug 0.0000 Dec 0.0000

How many sewer connections does this system have?   0
How many water service connections with septic systems does this system have?   1,129
Are there plans to build or expand wastewater treatment facilities in the next 10 years?   No

5. Planning

Projections
  2002 2010 2020 2030
Year-Round Population 2,740 3,345 3,500 3,750
Seasonal Population 0 0 0 0
 
Residential 0.1290 0.1670 0.1750 0.1880
Commercial 0.0010 0.0020 0.0020 0.0030
Industrial 0.0000 0.0000 0.0000 0.0000
Institutional 0.0000 0.0000 0.0000 0.0000
System Process 0.0090 0.0090 0.0100 0.0100
Unaccounted-for 0.0088 0.0100 0.0100 0.0100
Demand v/s Percent of Supply
  2002 2010 2020 2030
Surface Water Supply 0.0000 0.0000 0.0000 0.0000
Ground Water Supply 1.0800 1.0800 1.0800 1.0800
Purchases 0.0000 0.0000 0.0000 0.0000
Future Supplies 0.0000 0.0000 0.0000
Total Available Supply (MGD) 1.0800 1.0800 3.2400 3.2400
Service Area Demand 0.1478 0.1880 0.1970 0.2110
Sales 0.0000 0.0000 0.0000 0.0000
Future Sales 0.0000 0.0000 0.0000
Total Demand (MGD) 0.1478 0.1880 0.1970 0.2110
Demand as Percent of Supply 14% 17% 6% 7%

The purpose of the above chart is to show a general indication of how the long-term per capita water demand changes over time. The per capita water demand may actually be different than indicated due to seasonal populations and the accuracy of data submitted. Water systems that have calculated long-term per capita water demand based on a methodology that produces different results may submit their information in the notes field.

Your long-term water demand is 47 gallons per capita per day. What demand management practices do you plan to implement to reduce the per capita water demand (i.e. conduct regular water audits, implement a plumbing retrofit program, employ practices such as rainwater harvesting or reclaimed water)? If these practices are covered elsewhere in your plan, indicate where the practices are discussed here.    

Are there other demand management practices you will implement to reduce your future supply needs?   

What supplies other than the ones listed in future supplies are being considered to meet your future supply needs?   

How does the water system intend to implement the demand management and supply planning components above?   

Additional Information

Has this system participated in regional water supply or water use planning?  No

What major water supply reports or studies were used for planning?  

Please describe any other needs or issues regarding your water supply sources, any water system deficiencies or needed improvements (storage, treatment, etc.) or your ability to meet present and future water needs. Include both quantity and quality considerations, as well as financial, technical, managerial, permitting, and compliance issues:   

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.