Hobgood

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.

1. System Information

Contact Information

Complete

Water System Name: Hobgood   PWSID: 04-42-035
Mailing Address:PO. Box 217 207 Commerce St.
Hobgood, NC 27843
Ownership:Municipality
 
Contact Person:Thomas EllisTitle:Town Administrator
Phone:252-826-4573Cell/Mobile:252-578-1733
 
Secondary Contact:Renee Ellis Phone:252-826-4573
Mailing Address:PO Box 217
Hobgood, NC 27843
Cell/Mobile:252-578-1733
Distribution System
Line Type Size Range (Inches) Estimated % of lines
Asbestos Cement 4-8 13.00 %
Polyvinyl Chloride 2-12 87.00 %
What are the estimated total miles of distribution system lines?   18 Miles
How many feet of distribution lines were replaced during 2024?   0 Feet
How many feet of new water mains were added during 2024?   0 Feet
How many meters were replaced in 2024?   7
How old are the oldest meters in this system?   59 Year(s)
How many meters for outdoor water use, such as irrigation, are not billed for sewer services?   2
What is this system's finished water storage capacity?   0.1750 Million Gallons
Has water pressure been inadequate in any part of the system since last update? Line breaks that were repaired quickly should not be included.   No
Programs
Does this system have a program to work or flush hydrants?   Yes, Semi-Annually
Does this system have a valve exercise program?   No
Does this system have a cross-connection program?   No
Does this system have a program to replace meters?   Yes
Does this system have a plumbing retrofit program?   No
Does this system have an active water conservation public education program?   Yes
Does this system have a leak detection program?   No
Water Conservation
What type of rate structure is used?   Increasing Block
How much reclaimed water does this system use?   0.0000 MGD   For how many connections?   0
Does this system have an interconnection with another system capable of providing water in an emergency?   Yes

2. Water Use Information

Service Area
Sub-Basin(s)% of Service Population
Fishing Creek (15-2)78 %
Roanoke River (14-1)22 %
County(s)% of Service Population
Halifax78 %
Martin22 %
What was the year-round population served in 2024?   680
Has this system acquired another system since last report?   No
Water Use by Type
Type of Use Metered
Connections
Metered
Average Use (MGD)
Non-Metered
Connections
Non-Metered
Estimated Use (MGD)
Residential 233 0.0210 0 0.0000
Commercial 27 0.0009 0 0.0000
Industrial 0 0.0000 0 0.0000
Institutional 6 0.0029 0 0.0000

How much water was used for system processes (backwash, line cleaning, flushing, etc.)?   0.0095 MGD

Water Sales
Purchaser PWSID Average
Daily Sold
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Town of Scotland Neck 04-42-015 0.0000 0 No Emergency

3. Water Supply Sources

Monthly Withdrawals & Purchases
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Jan 0.0497 May 0.0500 Sep 0.0491
Feb 0.0341 Jun 0.0386 Oct 0.0495
Mar 0.0300 Jul 0.0671 Nov 0.0425
Apr 0.0420 Aug 0.0378 Dec 0.0455

Ground Water Sources
Name or Number Average Daily Withdrawal (MGD) Max Day Withdrawal (MGD) 12-Hour Supply
(MGD)
CUA Reduction Year Offline Use Type
MGD Days Used
1 0.0257 290 0.0792 Regular
2 0.0270 298 0.0864 Regular
3 0.0288 20 0.1800 Regular
4 0.0281 10 0.1730 Regular
Ground Water Sources (continued)
Name or Number Well Depth (Feet) Casing Depth
(Feet)
Screen Depth (Feet) Well Diameter (Inches) Pump Intake Depth (Feet) Metered?
Top Bottom
1 228 186 186 228 6 147 Yes
2 239 180 180 239 6 149 Yes
3 192 154 154 192 8 126 Yes
4 197 176 176 197 8 147 Yes
Are ground water levels monitored?   Yes, As Needed
Does this system have a wellhead protection program?   Yes
Water Purchases From Other Systems
Seller PWSID Average
Daily Purchased
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Town of Scotland Neck 04-42-015 0.0000 0 0.0000 No No 3 Emergency
Water Treatment Plants
Plant Name Permitted Capacity
(MGD)
Is Raw Water Metered? Is Finished Water Ouput Metered? Source
PO1 0.1530 Yes Yes Groundwater
PO2 0.1570 Yes Yes Groundwater
PO3 0.3380 Yes Yes Groundwater
PO4 0.3170 Yes Yes Groundwater
Did average daily water production exceed 80% of approved plant capacity for five consecutive days during 2024?  No
     If yes, was any water conservation implemented?  No
Did average daily water production exceed 90% of approved plant capacity for five consecutive days during 2024?  No
     If yes, was any water conservation implemented?  
Are peak day demands expected to exceed the water treatment plant capacity in the next 10 years?  No

4. Wastewater Information

Monthly Discharges
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Jan 0.0512 May 0.0195 Sep 0.0273
Feb 0.0231 Jun 0.0280 Oct 0.0356
Mar 0.0353 Jul 0.0223 Nov 0.0240
Apr 0.0355 Aug 0.0438 Dec 0.0205

How many sewer connections does this system have?   188
How many water service connections with septic systems does this system have?   0
Are there plans to build or expand wastewater treatment facilities in the next 10 years?   No
Wastewater Interconnections
Water System PWSID Type Average Daily Amount Contract
Maximum (MGD)
MGD Days Used
Town of Scotland Neck 04-42-015 Discharging 0.0306 365 0.0600

5. Planning

Projections
  2024 2030 2040 2050 2060 2070
Year-Round Population 680 685 690 695 700 705
Seasonal Population 0 0 0 0 0 0
 
Residential 0.0210 0.0240 0.0242 0.0245 0.0245 0.0250
Commercial 0.0009 0.0040 0.0045 0.0050 0.0055 0.0060
Industrial 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Institutional 0.0029 0.0030 0.0032 0.0035 0.0035 0.0035
System Process 0.0095 0.0030 0.0030 0.0035 0.0035 0.0035
Unaccounted-for 0.0104 0.0140 0.0140 0.0140 0.0140 0.0140
Demand v/s Percent of Supply
  2024 2030 2040 2050 2060 2070
Surface Water Supply 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Ground Water Supply 0.5186 0.5186 0.5186 0.5186 0.5186 0.5186
Purchases 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Supplies 0.0000 0.0000 0.0000 0.0000 0.0000
Total Available Supply (MGD) 0.5186 0.5186 0.5186 0.5186 0.5186 0.5186
Service Area Demand 0.0447 0.0480 0.0489 0.0505 0.0510 0.0520
Sales 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Sales 0.0000 0.0000 0.0000 0.0000 0.0000
Total Demand (MGD) 0.0447 0.0480 0.0489 0.0505 0.0510 0.0520
Demand as Percent of Supply 9% 9% 9% 10% 10% 10%

The purpose of the above chart is to show a general indication of how the long-term per capita water demand changes over time. The per capita water demand may actually be different than indicated due to seasonal populations and the accuracy of data submitted. Water systems that have calculated long-term per capita water demand based on a methodology that produces different results may submit their information in the notes field.

Your long-term water demand is 31 gallons per capita per day. What demand management practices do you plan to implement to reduce the per capita water demand (i.e. conduct regular water audits, implement a plumbing retrofit program, employ practices such as rainwater harvesting or reclaimed water)? If these practices are covered elsewhere in your plan, indicate where the practices are discussed here.    No changes

Are there other demand management practices you will implement to reduce your future supply needs?   No changes

What supplies other than the ones listed in future supplies are being considered to meet your future supply needs?   No changes

How does the water system intend to implement the demand management and supply planning components above?   No changes

Additional Information

Has this system participated in regional water supply or water use planning?  No

What major water supply reports or studies were used for planning?  

Please describe any other needs or issues regarding your water supply sources, any water system deficiencies or needed improvements (storage, treatment, etc.) or your ability to meet present and future water needs. Include both quantity and quality considerations, as well as financial, technical, managerial, permitting, and compliance issues:   

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.