Ahoskie

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.

1. System Information

Contact Information

Complete

Water System Name: Ahoskie   PWSID: 04-46-010
Mailing Address:P.O. Box 767
Ahoskie, NC 27910
Ownership:Municipality
 
Contact Person:Stephen LassiterTitle:Public Works Director
Phone:252-332-5165Cell/Mobile:--
 
Secondary Contact:Mike Houston Phone:919-812-6088
Mailing Address:
, NC 28525
Cell/Mobile:--
Distribution System
Line Type Size Range (Inches) Estimated % of lines
Asbestos Cement 6-8 45.00 %
Cast Iron 6-8 39.00 %
Galvanized Iron 2 1.00 %
Polyvinyl Chloride 2-16 15.00 %
What are the estimated total miles of distribution system lines?   34 Miles
How many feet of distribution lines were replaced during 2024?   0 Feet
How many feet of new water mains were added during 2024?   0 Feet
How many meters were replaced in 2024?   50
How old are the oldest meters in this system?   9 Year(s)
How many meters for outdoor water use, such as irrigation, are not billed for sewer services?   10
What is this system's finished water storage capacity?   0.8000 Million Gallons
Has water pressure been inadequate in any part of the system since last update? Line breaks that were repaired quickly should not be included.   No
Programs
Does this system have a program to work or flush hydrants?   Yes, Annually
Does this system have a valve exercise program?   No
Does this system have a cross-connection program?   Yes
Does this system have a program to replace meters?   Yes
Does this system have a plumbing retrofit program?   No
Does this system have an active water conservation public education program?   Yes
Does this system have a leak detection program?   Yes

The Town utilizes leak detection equipment and NCRWA on an as needed basis.

Water Conservation
What type of rate structure is used?   Flat/Fixed, Increasing Block
How much reclaimed water does this system use?   0.0000 MGD   For how many connections?   0
Does this system have an interconnection with another system capable of providing water in an emergency?   Yes

2. Water Use Information

Service Area
Sub-Basin(s)% of Service Population
Chowan River (04-1)100 %
County(s)% of Service Population
Hertford100 %
What was the year-round population served in 2024?   5,479
Has this system acquired another system since last report?   No
Water Use by Type
Type of Use Metered
Connections
Metered
Average Use (MGD)
Non-Metered
Connections
Non-Metered
Estimated Use (MGD)
Residential 1,860 0.2884 0 0.0000
Commercial 323 0.2240 0 0.0000
Industrial 0 0.0000 0 0.0000
Institutional 0 0.0000 0 0.0000

How much water was used for system processes (backwash, line cleaning, flushing, etc.)?   0.0300 MGD

Water Sales
Purchaser PWSID Average
Daily Sold
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Hertford Co (Connections 1,2) 04-46-045 0.0000 0 0.0120 Yes No 2-12 Emergency

3. Water Supply Sources

Monthly Withdrawals & Purchases
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Jan 0.8375 May 0.6539 Sep 0.6068
Feb 0.7474 Jun 0.7795 Oct 0.6176
Mar 0.9334 Jul 0.6692 Nov 0.7269
Apr 1.0903 Aug 0.6187 Dec 1.0593

Ground Water Sources
Name or Number Average Daily Withdrawal (MGD) Max Day Withdrawal (MGD) 12-Hour Supply
(MGD)
CUA Reduction Year Offline Use Type
MGD Days Used
01 0.1179 366 0.1800 Regular
03 0.1447 366 0.6820 Regular
04 0.1729 366 0.7350 Regular
4-A 0.1804 366 0.8800 Regular
5 0.0779 366 0.8040 Regular
5-A 0.1019 304 0.3770 Regular
Ground Water Sources (continued)
Name or Number Well Depth (Feet) Casing Depth
(Feet)
Screen Depth (Feet) Well Diameter (Inches) Pump Intake Depth (Feet) Metered?
Top Bottom
01 453 268 268 448 10 188 Yes
03 200 180 180 200 10 140 Yes
04 213 162 162 182 8 145 Yes
4-A 440 435 405 425 8 433 Yes
5 433 433 411 423 8 433 Yes
5-A 237 217 175 227 8 217 Yes
Are ground water levels monitored?   Yes, Quarterly
Does this system have a wellhead protection program?   Yes
Water Purchases From Other Systems
Seller PWSID Average
Daily Purchased
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Hertford Co (Connections 1,2) 04-46-045 0.0000 0 0.0000 Yes No 8-12 Emergency

4. Wastewater Information

Monthly Discharges
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Jan 0.8375 May 0.6539 Sep 0.6068
Feb 0.7474 Jun 0.7795 Oct 0.6176
Mar 0.9344 Jul 0.6692 Nov 0.7269
Apr 1.0903 Aug 0.6177 Dec 1.0617

How many sewer connections does this system have?   2,300
How many water service connections with septic systems does this system have?   40
Are there plans to build or expand wastewater treatment facilities in the next 10 years?   No
Wastewater Permits
Permit Number Type Permitted Capacity
(MGD)
Design Capacity
(MGD)
Average Annual
Daily Discharge
(MGD)
Maximum Day Discharge
(MGD)
Receiving Stream Receiving Basin
WQ0003885 WWTP 1.7060 1.7060 0.7785 Ahoskie Creek Chowan River (04-1)
Wastewater Interconnections
Water System PWSID Type Average Daily Amount Contract
Maximum (MGD)
MGD Days Used
Powellsville 04-08-040 Receiving 0.0216 366

5. Planning

Projections
  2024 2030 2040 2050 2060 2070
Year-Round Population 5,479 5,486 5,497 5,506 5,516 5,526
Seasonal Population 0 0 0 0 0 0
 
Residential 0.2884 0.2887 0.2892 0.2897 0.2902 0.2907
Commercial 0.2240 0.2242 0.2246 0.2250 0.2254 0.2258
Industrial 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Institutional 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
System Process 0.0300 0.0300 0.0300 0.0300 0.0300 0.0300
Unaccounted-for 0.2360 0.2362 0.2366 0.2370 0.2374 0.2378
Demand v/s Percent of Supply
  2024 2030 2040 2050 2060 2070
Surface Water Supply 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Ground Water Supply 3.6580 3.6580 3.6580 3.6580 3.6580 3.6580
Purchases 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Supplies 0.0000 0.0000 0.0000 0.0000 0.0000
Total Available Supply (MGD) 3.6580 3.6580 3.6580 3.6580 3.6580 3.6580
Service Area Demand 0.7784 0.7791 0.7804 0.7817 0.7830 0.7843
Sales 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Sales 0.0000 0.0000 0.0000 0.0000 0.0000
Total Demand (MGD) 0.7784 0.7791 0.7804 0.7817 0.7830 0.7843
Demand as Percent of Supply 21% 21% 21% 21% 21% 21%

The purpose of the above chart is to show a general indication of how the long-term per capita water demand changes over time. The per capita water demand may actually be different than indicated due to seasonal populations and the accuracy of data submitted. Water systems that have calculated long-term per capita water demand based on a methodology that produces different results may submit their information in the notes field.

Your long-term water demand is 53 gallons per capita per day. What demand management practices do you plan to implement to reduce the per capita water demand (i.e. conduct regular water audits, implement a plumbing retrofit program, employ practices such as rainwater harvesting or reclaimed water)? If these practices are covered elsewhere in your plan, indicate where the practices are discussed here.    No Changes

Are there other demand management practices you will implement to reduce your future supply needs?   No Changes

What supplies other than the ones listed in future supplies are being considered to meet your future supply needs?   No Changes

How does the water system intend to implement the demand management and supply planning components above?   No Changes

Additional Information

Has this system participated in regional water supply or water use planning?  No

What major water supply reports or studies were used for planning?  

Please describe any other needs or issues regarding your water supply sources, any water system deficiencies or needed improvements (storage, treatment, etc.) or your ability to meet present and future water needs. Include both quantity and quality considerations, as well as financial, technical, managerial, permitting, and compliance issues:   

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.