Blowing Rock

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.

1. System Information

Contact Information

Provisional

Water System Name: Blowing Rock   PWSID: 01-95-020
Mailing Address:PO Box 47
Blowing Rock, NC 28605
Ownership:Municipality
 
Contact Person:Lane BaileyTitle:Town Manager
Phone:828-295-5200Cell/Mobile:--
 
Secondary Contact:Matt Blackburn Phone:828-295-5200
Mailing Address:P.O. Box 47
Blowing Rock, NC 28605
Cell/Mobile:--
Distribution System
Line Type Size Range (Inches) Estimated % of lines
Cast Iron 6-8 38.00 %
Ductile Iron 6-12 52.00 %
Polyvinyl Chloride 6-8 10.00 %
What are the estimated total miles of distribution system lines?   21 Miles
How many feet of distribution lines were replaced during 2025?   0 Feet
How many feet of new water mains were added during 2025?   0 Feet
How many meters were replaced in 2025?   15
How old are the oldest meters in this system?   18 Year(s)
How many meters for outdoor water use, such as irrigation, are not billed for sewer services?   0
What is this system's finished water storage capacity?   3.5000 Million Gallons
Has water pressure been inadequate in any part of the system since last update? Line breaks that were repaired quickly should not be included.   No
Programs
Does this system have a program to work or flush hydrants?   Yes, Annually
Does this system have a valve exercise program?   Yes, As Needed
Does this system have a cross-connection program?   Yes
Does this system have a program to replace meters?   Yes
Does this system have a plumbing retrofit program?   No
Does this system have an active water conservation public education program?   Yes
Does this system have a leak detection program?   No
Water Conservation
What type of rate structure is used?   Uniform
How much reclaimed water does this system use?   0.0000 MGD   For how many connections?   0
Does this system have an interconnection with another system capable of providing water in an emergency?   Yes

2. Water Use Information

Service Area
Sub-Basin(s)% of Service Population
New River (11-1)76 %
Catawba River (03-1)20 %
Yadkin River (18-1)4 %
County(s)% of Service Population
Watauga95 %
Caldwell5 %
What was the year-round population served in 2025?   1,637
Has this system acquired another system since last report?   No
Water Use by Type
Type of Use Metered
Connections
Metered
Average Use (MGD)
Non-Metered
Connections
Non-Metered
Estimated Use (MGD)
Residential 2,345 0.2153 0 0.0000
Commercial 347 0.0789 0 0.0000
Industrial 0 0.0000 0 0.0000
Institutional 0 0.0000 0 0.0000

How much water was used for system processes (backwash, line cleaning, flushing, etc.)?   0.0095 MGD

Water Sales
Purchaser PWSID Average
Daily Sold
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Boone 01-95-010 0.0000 0 Yes 12 Emergency

3. Water Supply Sources

Monthly Withdrawals & Purchases
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Average Daily
Use (MGD)
Max Day
Use (MGD)
Jan 0.5862 May 0.4676 Sep 0.4636
Feb 0.6648 Jun 0.5054 Oct 0.4064
Mar 0.3554 Jul 0.5705 Nov 0.3821
Apr 0.4405 Aug 0.4975 Dec 0.3888

Several large leaks in January and February.

Surface Water Sources
Stream Reservoir Average Daily Withdrawal Maximum Day
Withdrawal (MGD)
Available Raw
Water Supply
Usable On-Stream
Raw Water Supply
Storage (MG)
MGD Days Used MGD * Qualifier
Flat Top Branch Blowing Rock 0.4785 333 0.0000 0.4000 SY20 47.0000

* Qualifier: C=Contract Amount, SY20=20-year Safe Yield, SY50=50-year Safe Yield, F=20% of 7Q10 or other instream flow requirement, CUA=Capacity Use Area Permit

Surface Water Sources (continued)
Stream Reservoir Drainage Area
(sq mi)
Metered? Sub-Basin County Year
Offline
Use
Type
Flat Top Branch Blowing Rock 1 Yes New River (11-1) Watauga Regular
What is this system's off-stream raw water supply storage capacity?   0 Million gallons
Are surface water sources monitored?   Yes, Daily
Are you required to maintain minimum flows downstream of its intake or dam?   No
Does this system anticipate transferring surface water between river basins?   No
Water Purchases From Other Systems
Seller PWSID Average
Daily Purchased
(MGD)
Days
Used
Contract Required to
comply with water
use restrictions?
Pipe Size(s)
(Inches)
Use
Type
MGD Expiration Recurring
Boone 01-95-010 0.0000 0 No 12 Emergency
Water Treatment Plants
Plant Name Permitted Capacity
(MGD)
Is Raw Water Metered? Is Finished Water Ouput Metered? Source
BLOWING ROCK WTP 1.0000 Yes Yes BLOWING ROCK RESERVOIR
Did average daily water production exceed 80% of approved plant capacity for five consecutive days during 2025?  No
     If yes, was any water conservation implemented?  
Did average daily water production exceed 90% of approved plant capacity for five consecutive days during 2025?  No
     If yes, was any water conservation implemented?  
Are peak day demands expected to exceed the water treatment plant capacity in the next 10 years?  Yes

4. Wastewater Information

Monthly Discharges
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Average Daily
Discharge (MGD)
Jan 0.2717 May 0.3875 Sep 0.2633
Feb 0.2755 Jun 0.3510 Oct 0.2572
Mar 0.2123 Jul 0.3278 Nov 0.1964
Apr 0.2606 Aug 0.3094 Dec 0.2039

How many sewer connections does this system have?   2,294
How many water service connections with septic systems does this system have?   421
Are there plans to build or expand wastewater treatment facilities in the next 10 years?   No
Wastewater Permits
Permit Number Type Permitted Capacity
(MGD)
Design Capacity
(MGD)
Average Annual
Daily Discharge
(MGD)
Maximum Day Discharge
(MGD)
Receiving Stream Receiving Basin
NC0027286 WWTP 0.8000 0.8000 0.2774 SF OF MIDDLE FORK OF NEW RIVER New River (11-1)

5. Planning

Projections
  2025 2030 2040 2050 2060 2070
Year-Round Population 1,637 1,678 1,720 1,763 1,810 1,860
Seasonal Population 0 8,200 8,405 8,615 8,831 9,050
 
Residential 0.2153 0.2200 0.2390 0.2500 0.2700 0.2850
Commercial 0.0789 0.0850 0.0920 0.1050 0.1150 0.1310
Industrial 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Institutional 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
System Process 0.0095 0.0100 0.0110 0.0120 0.0130 0.0140
Unaccounted-for 0.1328 0.1377 0.1495 0.1605 0.1740 0.1880
Demand v/s Percent of Supply
  2025 2030 2040 2050 2060 2070
Surface Water Supply 0.4000 0.4000 0.4000 0.4000 0.4000 0.4000
Ground Water Supply 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Purchases 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Supplies 0.0000 0.0000 0.0000 0.0000 0.0000
Total Available Supply (MGD) 0.4000 0.4000 0.4000 0.4000 0.4000 0.4000
Service Area Demand 0.4365 0.4527 0.4915 0.5275 0.5720 0.6180
Sales 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Future Sales 0.0000 0.0000 0.0000 0.0000 0.0000
Total Demand (MGD) 0.4365 0.4527 0.4915 0.5275 0.5720 0.6180
Demand as Percent of Supply 109% 113% 123% 132% 143% 155%

The purpose of the above chart is to show a general indication of how the long-term per capita water demand changes over time. The per capita water demand may actually be different than indicated due to seasonal populations and the accuracy of data submitted. Water systems that have calculated long-term per capita water demand based on a methodology that produces different results may submit their information in the notes field.

Your long-term water demand is 132 gallons per capita per day. What demand management practices do you plan to implement to reduce the per capita water demand (i.e. conduct regular water audits, implement a plumbing retrofit program, employ practices such as rainwater harvesting or reclaimed water)? If these practices are covered elsewhere in your plan, indicate where the practices are discussed here.    No Changes.

Are there other demand management practices you will implement to reduce your future supply needs?   None

What supplies other than the ones listed in future supplies are being considered to meet your future supply needs?   None

How does the water system intend to implement the demand management and supply planning components above?   N/A

Additional Information

Has this system participated in regional water supply or water use planning?  No

What major water supply reports or studies were used for planning?  None

Please describe any other needs or issues regarding your water supply sources, any water system deficiencies or needed improvements (storage, treatment, etc.) or your ability to meet present and future water needs. Include both quantity and quality considerations, as well as financial, technical, managerial, permitting, and compliance issues:   None

The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR.